Interface Overview, Drive Control - Siemens SIMODRIVE 611 Planning Manual

Drive converter
Hide thumbs Also See for SIMODRIVE 611:
Table of Contents

Advertisement

5 Control Modules
5.6 Drive control with digital setpoint interface
5
5.6.1
Table 5-16
Term.
No.
9
663
AS1
AS2
B1
19
B2
9
_________
1)
2)
5-126
Notice
When using non–PELV circuits connected to terminals AS1, AS2, the connec-
tor must be prevented from being incorrectly inserted using plug coding (refer
to EN60204–1, Section 6.4).
Order No. of the coding, refer to Catalog NC 60.
Warning
!
Only PELV circuits may be connected to terminal 19.

Interface overview, drive control

Interface overview, drive control
Desig.
X431
Enable potential 2)
X431
Pulse enable: The "start inhibit" relay is switched
using terminal 663; when it opens, the gating pulses
are inhibited and the motor is switched into a no–
torque condition.
X431
Relay, start inhibit (feedback signal. term. 663)
X431
Relay, start inhibit (feedback signal, term. 663)
X432
Input, external zero mark (BERO) axis 1
X432
negative enable potential
X432
Input, external zero mark (BERO) axis 2
X432
positive enable potential 2)
X411
Motor encoder, axis 1
X412
Motor encoder, axis 2
X421
Direct position encoder axis 1
X422
Direct position encoder axis 2
X151
Equipment bus (not labeled on the front panel)
X141/341
Drive bus
I=Input; O=Output; NC=NC contact; NO=NO contact (for signal NO=High/NC=Low)
The terminal may only be used to enable the associated drive group.
Function
SIMODRIVE 611 Planning Guide (PJU) – 05.01 Edition
Type
Typ. voltage/
Max. cross–
1)
limit values
sect.
O
+24 V
1.5 mm
I
+21 V ... 30 V
1.5 mm
max. 250VAC/1A
1.5 mm
NC
30 VDC/2 A
1.5 mm
I
+13 ... 30 V
1.5 mm
O
0 V
1.5 mm
I
+13 ... 30 V
1.5 mm
O
+24 V
1.5 mm
 Siemens AG 2001 All rights reserved
05.01
2
2
2
2
2
2
2
2