6 Infeed Modules
6.5 Monitoring module
6.5.3
6.5.4
6
6-186
Technical data (supplements the general technical data)
Table 6-8
Power loss
Alternative, rated supply voltage
DC link
Cooling type
Weight
Checking the permissible power supply rating
The infeed or monitoring module used offers a basic equipping of the electro-
nics (EP values) and gating power supply (AP values).
The power supply requirement of a drive group is determined using Table 6-12.
The number of all of the modules used should be entered. It is the product of
»assessment factor, individual module« and »number of modules«.
If one of these values is exceeded, then an (additional) monitoring module must
be provided. In this case, Table 6-12 must be re–applied for the module group,
which is supplied from the monitoring module.
The monitoring module must be located to the left in front of the modules to be
monitored.
Technical data, monitoring module
70 W
600/625/690 V DC
Non–ventilated
4 kg
SIMODRIVE 611 Planning Guide (PJU) – 05.01 Edition
05.01
Siemens AG 2001 All rights reserved