System Configurations And Cable Connections - Siemens SIMODRIVE 611 Planning Manual

Drive converter
Hide thumbs Also See for SIMODRIVE 611:
Table of Contents

Advertisement

05.01
3.6.3

System configurations and cable connections

1PH2 motor
HGL is not required in this configuration.
without C–axis
operation
Fig. 3-11
1PH2 motors with
C–axis operation
Fig. 3-12
 Siemens AG 2001 All rights reserved
SIMODRIVE 611 Planning Guide (PJU) – 05.01 Edition
3 Motor Selection, Position/Speed Sensing
Toothed/measuring wheel
1PH2~
Sensing
head
Drive
converter
611A
X412
6FX2002–2CB1 1–0VVV
X432
n
x pulse number/360
1
n
= 1; 2; 4; 8
1
System configuration, 1PH2 motor without C–axis operation
Toothed/measuring wheel
1PH2~
Sensing head
Drive
converter
~
X412
611A
HGL
X512
6FC9348–0FY
X511
6FX2002–2CB1 1–0VVV
X521
n
x pulse number/360
1
n
= 1; 2; 4; 8
1
X522
n
x 175.78125 x pulse number/360
2
n
= 1; 2
2
n
, n
= can be selected via switch S1
1
2
System configuration, 1PH2 motor with C–axis operation
3.6 High–resolution position (HGL)
Chuck
Spindle
6FX2002–2CA31–0 VVV
~
Measuring
circuit 1,
standard
0
mech
track
Chuck
Spindle
~
6FX2002–2CA51–0 VVV
Measuring
circuit 1,
standard
0
mech
track
Measuring
circuit 2,
C–axis track
0
mech
Workpiece
NC
Workpiece
NC
3-77
3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents