Specifications - Omron SYSMAC CS Series Operation Manual

Profibus master units
Hide thumbs Also See for SYSMAC CS Series:
Table of Contents

Advertisement

CX-Profibus Configurator
1-4-2

Specifications

Functional Specifications
Item
Model number
Hardware platform
Operating System
Connection to CS1/CJ1W-PRM21
Connection to C200HW-PRM21
General Project functions
Network setup functions
Device Catalogue functions
Support functions
22
WS02-9094G
• Personal computer: IBM PC/AT or compatible
• Processor: Pentium 500 MHz or higher
• Memory: 256 Mbytes
• Hard disk: A minimum of 256 Mbytes
• CD-ROM drive
• Graphics resolution: 800 x 600 pixels minimum
• Serial port: RS-232C
• MS Windows NT4.0, SP6
• MS Windows 2000, SP2
• MS Windows XP
Note Internet Explorer 5.01 is also required.
• Peripheral or RS-232C port of PC with PLC CPU. Serial communica-
tions mode: Peripheral bus, Host Link, Toolbus, supported by CX-
Server.
• Communication cable: Cable CS1W-CN226 to connect to the periph-
eral port on the CPU (Not included in package).
• RS-232C port of PC with Configuration port on the Unit.
File handling: CX-Profibus supports overall handling of project files as
well as network data.
• New:
Start a new project.
• Open:
Open an existing project file.
• Save (As): Save a project file.
• Export:
Export project data to HTML.
• Properties:Edit project property information.
User management: Functionality of CX-Profibus can be limited as
defined by several password protected access levels:
• Administrator
• Planning engineer
• Maintenance
• Operator
• Observer
CX-Profibus provides network tree view, from which hierarchy between
Master and slave devices can clearly be distinguished.
The following network functions are available:
• Network DTMs (i.e. devices) can be added or deleted, using drag and
drop from the Device Catalogue.
• Network DTMs can be copied and moved from one location to
another in the network view.
• DTM names can be edited by the user.
• Any change to the parameters of a DTM is clearly marked in the tree
view, until the project is downloaded to the Master Unit.
The Device Catalogue maintains the installed device DTMs. After instal-
lation of a new DTM, the user must refresh the database. The Device
Catalogue provides the following functions:
• Update Device Catalogue.
• Add device DTMs to the network directly.
• Install a GSD file. This function allows copying of GSD files to a spe-
cific directory, after which they are available for the Generic Slave
DTM.
CX-Profibus provides the following additional support functions:
• Context sensitive help functions.
• Error logging.
• Monitoring of FDT communication between DTMs.
• Multi-language support.
Specification
Section 1-4

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sysmac cj-seriesSysmac cj1w-prm21Sysmac cs1w-prm21

Table of Contents