Omron SYSMAC CS Series Operation Manual page 96

Profibus master units
Hide thumbs Also See for SYSMAC CS Series:
Table of Contents

Advertisement

CS1/CJ1W-PRM21 PROFIBUS Master DTM
Note
Acyclic Connection Status
Flags
Bit
Name
Acyclic Connection
flags
The Acyclic Connection/Abort status box contains the following information.
Control
Area
Start Address
Length
1. If the selected PLC memory area, on to which the data must be mapped is
not supported by the PLC CPU, a warning message will be displayed upon
downloading the configuration.
2. If an invalid setting is made the Length value will change its colour to red,
indicating an invalid setting. In addition, a warning message will be dis-
played, upon saving the changes. Invalid settings are for example
• The start address and length definitions of the data block will cause it
to exceed the area in the PLC.
• The mapping overlaps with one or more of the I/O Areas (Output and/
or Input) mappings.
The 8 word Acyclic Connection bit flags are shown below.
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Word n
15
14
13
Word n+1
31
30
29
Word n+2
47
46
45
Word n+3
63
62
61
Word n+4
79
78
77
Word n+5
95
94
93
Word n+6
111 110 109 108 107 106 105 104 103 102 101 100 99
Word n+7
125 124 123 122 121 120 119 118 117 116 115 114 113 112
Note In the above figure, n is the start address of the memory locations, defined by
the Area and Start Address setting in the Acyclic Connection/Abort Status
Box.
Status Controlled
by
ON
Unit
If the bit corresponding to a slave device address is ON, it indicates that
the PROFIBUS Master Unit has established a PROFIBUS DP-V1 Class
2 type connection.
OFF
Unit
If the bit corresponding to a slave device address is OFF, it indicates
that there is no open PROFIBUS DP-V1 Class 2 type connection with
the specific slave device.
Selects the PLC memory area to which the Acyclic Con-
nection/Abort status bits will be mapped. Possible
options are (See Note):
• Not Used (Default setting, Start Address and Length
will be set to 0).
• CIO
• DM
• Work
• HR
• EM Bank 0 to 12 (Decimal)
In this field the user can enter the start address in the
PLC memory of the mapped data block.
The length value is a fixed number. The total number of
words is 16.
12
11
10
9
8
7
6
5
28
27
26
25
24
23
22
21
44
43
42
41
40
39
38
37
60
59
58
57
56
55
54
53
76
75
74
73
72
71
70
69
92
91
90
89
88
87
86
85
Unit operation
Section 3-3
Description
Slave station 00 ~ 15
4
3
2
1
0
Slave station 16 ~ 31
20
19
18
17
16
Slave station 32 ~ 47
36
35
34
33
32
Slave station 48 ~ 63
52
51
50
49
48
Slave station 64 ~ 79
68
67
66
65
64
Slave station 80 ~ 95
84
83
82
81
80
Slave station 96 ~ 111
98
97
96
Slave station 112 ~ 125
75

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sysmac cj-seriesSysmac cj1w-prm21Sysmac cs1w-prm21

Table of Contents