REFRIGERANT RECOVERY
WARNING:
Avoid breathing air conditioning refrigerant or lubricant vapor. Exposure may irritate eyes, nose and
•
throat. Also, due to environmental concerns, use service equipment certified to meet the requirements of
SAE J2210 (R-134a recycling equipment) when draining R-134a from the air conditioning system. If
accidental system discharge occurs, ventilate work area before resuming service.
1. Connect an R-134a recovery/recycling/recharging device to the vehicle and follow the device
manufacturer's instructions.
REFRIGERANT CHARGING
WARNING:
Avoid breathing air conditioning refrigerant or lubricant vapor. Exposure may irritate eyes, nose and
•
throat. Also, due to environmental concerns, use service equipment certified to meet the requirements of
SAE J2210 (R-134a recycling equipment) when draining R-134a from the air conditioning system. If
accidental system discharge occurs, ventilate work area before resuming service.
CAUTION:
Do not exceed the specification when charging the system with refrigerant. Doing so will decrease the
•
efficiency of the air conditioner or damage the refrigeration cycle parts.
(w)
RX-8 - HVAC