Diagnostic Procedure
STEP INSPECTION
VERIFY WHETHER KEY IS VALID OR
NOT
Using another registered key, turn the
•
ignition switch to the ON position.
If there is not another registered key, register
•
an additional key using the WDS or
equivalent and turn the ignition key to the
ON position using the registered key.
1
(See IMMOBILIZER SYSTEM
COMPONENT REPLACEMENT/KEY
ADDITION AND CLEARING .)
Is the DTC displayed again?
•
SECURITY LIGHT: 14
WDS or equivalent: B1602/P1260
INSPECT KEYLESS CONTROL MODULE
Using another registered key, turn the
•
ignition switch to the ON position.
2
Is the DTC displayed again?
•
SECURITY LIGHT: 14
WDS or equivalent: B1602/P1260
ACTION
Replace the coil, then go to the next step.
Yes
(See COIL REMOVAL/INSTALLATION .)
Dispose of the malfunctioning key.
•
Register a new key if necessary.
•
No
(See IMMOBILIZER SYSTEM
COMPONENT
REPLACEMENT/KEY ADDITION
AND CLEARING .)
Replace the keyless control module and
perform procedures for when replacing the
keyless control module only.
(See KEYLESS CONTROL MODULE
Yes
REMOVAL/INSTALLATION .)
(See IMMOBILIZER SYSTEM
COMPONENT REPLACEMENT/KEY
ADDITION AND CLEARING .)
No DTC troubleshooting completed.
(w)
RX-8 Body