BRAKE FLUID PRESSURE SENSOR
BRAKE FLUID PRESSURE SENSOR INSPECTION
1. Turn the ignition switch to the ON position, then measure the voltage between brake fluid pressure
sensor terminal C and ground.
If there is any malfunction, inspect the wiring harness between brake fluid pressure sensor
•
terminal C and DSC HU/CM terminal C, then repair or replace if necessary.
Standard voltage
4.755.25 V
o
2. Measure the voltage between brake fluid pressure sensor terminal A and the ground.
If there is any malfunction, inspect the wiring harness between brake fluid pressure sensor
•
terminal A and DSC HU/CM terminal E, then repair or replace if necessary.
Standard voltage
0 V
o
3. Turn the ignition switch off.
4. Install the SSTs to the master cylinder.
NOTE:
Install the SST (49 D043 002) to the master cylinder using a commercially available flare nut
•
wrench.
Flare nut across flat: 12 mm {0.47 in}
5. Bleed the air from the SSTs and the brake line. (Bleed air from the SSTs through air bleeding valve A.)
6. Connect the WDS or equivalent to the DLC-2.
(w)
RX8 - Brakes
Page 63