INSPECT DOOR LOCK LINKAGE
Operate the door lock knob and verify the door
12
locks and unlocks manually.
Does every door lock system work?
INSPECT IF MALFUNCTION IS IN DOOR
LOCK ACTUATOR, KEYLESS CONTROL
MODULE GROUND CIRCUIT OR ELSEWHERE
Measure the voltage at keyless control module
connector terminals 1C and 1D.
*13
All doors locked: Cycles 1.0 V or less →
B+ → 1.0 V or less (terminal 1D)
All doors unlocked: Cycles B+ → 1.0 V
or less → B+ (terminal 1C)
Is the voltage as above?
REINSPECT MALFUNCTION SYMPTOM
AFTER REPAIR
14
Does the keyless entry system operate properly?
Yes Go to the next step.
No Inspect the door lock linkage.
Reinspect the malfunction symptoms,
Yes
then repeat from Step 1 if the
malfunction recurs.
Inspect the keyless control
module the connector.
Inspect the wiring harness
between the keyless control
module and door lock actuator.
No
If the above parts are
normal, go to the next
step.
If any of above parts are
malfunctioning, repair the
malfunctioning part.
Troubleshooting completed.
Yes
Explain repairs to customer.
Reinspect the malfunction symptoms,
No
then repeat from Step 1 if malfunction
recurs.