Installing the Remote Office 9150 unit

Mounting the Remote Office 9150 unit

The Remote Office 9150 unit can be installed
n
on a desk (see below)
n
on a wall (see page 108)
n
in a rack (see page 110)
The Remote Office 9150 unit package contains the following hardware:
n
rubber feet for installing the Remote Office 9150 unit on a desk
n
brackets with screws for installing the Remote Office 9150 unit in a rack
If you want to mount the Remote Office 9150 unit on a wall, you must provide
your own mounting hardware.
Choosing a suitable location
The Remote Office 9150 unit dimensions are
n
42.5 cm (17 in.) wide (without rack-mounting brackets)
n
29.4 cm (11.75 in.) deep
n
4.4 cm (1.75 in.) high
For guidelines on where to install the Remote Office 9150 unit, see "Physical
environment" on page 56.
Note: It is recommended that you install the Remote Office 9150 unit in the
same room where your communications equipment is installed. The Remote
Office 9150 unit should be located no further than
n
1230.7 m (4000 ft) from the digital telephones
n
307.7 m (1000 ft) from the analog device
106
Standard 2.0
Remote Office 9150