LPOD-R Outdoor Amplifier / Block Up Converter
Ethernet Interface Operation
4.5.4 Status Pages
Use these pages to see the unit's operational status, logged alarm and statistics
windows. Click Summary, Status, MOP, Events, Statistics, or Trending Graphs to
continue.
4.5.4.1 Status | Summary
This read-only page shows a summary of information about the LPOD-R unit and
its current operating state. Refresh the page to see the latest data.
Figure 4-11. Status | Summary Page
Summary (read only)
The Summary Fault message shows OK on a green background if no faults are
present. If a fault exists, the message changes to FAULT on a red background.
Should this occur, look at the logged faults and alarms on the Status | Events
page.
Terminal Status Change
If Terminal Status Change shows NO, there have been no changes in the unit's
configuration since the last time the Terminal Status Change status was cleared.
If Terminal Status Change shows YES, a status change had occured for one or
more of these reasons:
• An operating parameter changed, (e.g., when a command changes an
operational value)
• A fault condition occurs
• A redundant switchover occurs
4–18
MN-LPODR
Revision 3