Comtech EF Data LPOD-R PS .5 Installation And Operation Manual page 126

Outdoor amplifier / block up converter (buc)
Table of Contents

Advertisement

LPOD-R Outdoor Amplifier / Block Up Converter (BUC)
Optional Serial Interface Operation (PS 1, PS 1.5 ONLY)
Controller-to-Target
Instruction Code and
Parameter Type
Qualifier
(* indicates
End-of-Life)
Command
Query
Retrieve Next 5
N/A
RNS?
unread stored
Statistics
Serial Number
N/A
RSN?
Summary Fault
N/A
SFS?
Status
Set FSK Address
SFA=
SFA?
SNMP
SNA=
SNA?
Authentication
Trap Enable
Arguments for
Command or
Response to
Query
75 bytes
Query only.
Unit returns the oldest 5 Stored Statistics that have not yet been read over the remote interface, in the form
{CR}Sub-body{CR}Sub-body{CR}Sub-body{CR}Sub-body{CR}Sub-body, where Sub-body is in the form
ddmmyyhhmmssaaa.abbb.bccc.cdd.ddefghhh.hiii.i:
ddmmyy = Date in day/month/year format
hhmmss = Time in hour:minutes:seconds format
aaa.a = Operating Temperature (I.E. +30.0) (PS 1.5 ONLY)
bbb.b = Amp Temperature (I.E. +40.0)
ccc.c = RF Power output
dd.dd = Attenuation Setting
e = Amp On/Off
f = Mute On/Off
g = Online/Offline Status (NOT USED)
hhh.h = LNB Current (mA) (NOT USED)
iii.i = BUC Tuning Voltage (VALID ONLY WHEN OPTIONAL BUC IS INSTALLED)
NOTES:
1)
If less than 5 entries are retrieved, the remaining positions are padded with zeros.
2)
If there are no new entries, the response is RNS*.
9 bytes
Query only.
Returns the unit's nine-digit serial number in the form xxxxxxxxx.
EXAMPLE: <0001/RSN?{CR}
>0001/RSN=0123445678{CR}{LF}
1 byte
Query only.
Returns the summary fault state in the form x, where:
0 = Not Faulted (SumFLT_COM J6 pin K is not connected to SumFLT_NC J6 pin M)
1 = Faulted (SumFLT_COM J6 pin K is connected to SumFLT_NC J6 pin M)
EXAMPLE: <0001/SFS?{CR}
>0001/SFS=0{CR}{LF}
2 bytes,
Command or Query.
numeric
Sets or returns the FSK Address in the form xx, where:
xx = Address value from 01 (DEFAULT) to 15.
COMMAND EXAMPLE: <0001/SFA=01{CR}
1 byte
Command or Query.
Sets or returns the SNMP Authentication Trap in the form x, where:
0 = Disabled
1 = Enabled
COMMAND EXAMPLE: <0001/SNA=0{CR}
Description of Arguments
(Note that all arguments are ASCII numeric codes from 48 to 57)
5–22
MN-LPODR
Revision 3
Target-to-Controller
(see Description of Arguments)
Response to
Response to
Command
Query
RNS=
RNS={CR}Sub-
body{CR}Sub-
body{CR}Sub-
body{CR}Sub-
body{CR}Sub-
body
RSN=
RSN=xxxxxxxxx
SFS=
SFS=x
SFA =
SFA=xx
SFA?
SFA*
SNA=
SNA=x
SNA?

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lpod-r ps 1.5Lpod-r ps 1Lpod-r series

Table of Contents