LPOD-R Outdoor Amplifier / Block Up Converter
Ethernet Interface Operation
• Select Initialize Statistics Pointer to reset the internal pointer to allow
queries to start at the beginning of the statistics log.
Click Submit to update the window according to your selection.
Statistics Configuration
• Statistics Interval – Enter the interval at which statistics are logged.
The interval is set in minutes. Minimum resolution is 1 minute (001);
maximum is 99 minutes (099). Default is 90 minutes (090).
• Statistics Averaging – Select Enable or Disable to set the Statistics
Averaging function:
o If Enabled, statistics data is averaged at a rate of once per second
for 10 seconds.
o If Disabled, burst values are logged instead of averaged values.
Click Submit to save the changes.
4–22
MN-LPODR