LPOD-R Outdoor Amplifier / Block Up Converter (BUC)
Optional Serial Interface Operation (PS 1, PS 1.5 ONLY)
Controller-to-Target
Instruction Code and
Parameter Type
Qualifier
(* indicates
End-of-Life)
Command
Query
Concise Alarm
N/A
CAS?
Status
Arguments for
Command or
Response to
Query
44 bytes
Query only.
Returns the Alarm status of the unit, response is semicolon delimited, in the form
a;b;c;d;e;f;g;h;i;j;k;I;m;n;o;p;q;r;s;t;u;v;w;x;y;z where:
a thru z = 0, 1, 2, 3, 4, or 5
0 = FT, 1 = OK, 2 = AL, 3 = NO, 4 = YS, 5 = MS
a = +24V Power Supply
b = +24V Power Supply (NOT USED)
c = +13/18V LNB Power Supply (NOT USED)
d = +13.5V Power Supply
e = +10V Power Supply
f = +10V1 RF Amplifier Power Supply
g = +10V2 RF Amplifier Power Supply (NOT USED)
h = +7.8V Power Supply
i = +5.8V Power Supply
j = +2.5V Power Supply
k = +1.2V Power Supply
l = -5.8V Power Supply
m = Fan#1 State
n = Fan#2 State (PS 1.5 ONLY)
o = Heatsink Temp
p = Overtemp Shutdown
q = llC Status
r = Forward Power Alarm
s = Flash Checksum
t = FPGA Done
u = BUC Lock Detect (NOT USED)
v = External Ref Lock Detect (NOT USED)
w = LNB Current (NOT USED)
x = Redundant Switch Condition (NOT USED)
y = Redundant Link Status (NOT USED)
z = Terminal Status Change
NOTE: This is the condensed version of the RAS query.
Description of Arguments
(Note that all arguments are ASCII numeric codes from 48 to 57)