Comtech EF Data LPOD-R PS .5 Installation And Operation Manual page 122

Outdoor amplifier / block up converter (buc)
Table of Contents

Advertisement

LPOD-R Outdoor Amplifier / Block Up Converter (BUC)
Optional Serial Interface Operation (PS 1, PS 1.5 ONLY)
Controller-to-Target
Instruction Code and
Parameter Type
Qualifier
(* indicates
End-of-Life)
Command
Query
Reboot
RBT=
N/A
Retrieve
N/A
RCS?
Configuration
Status
Retrieve
N/A
RET?
Equipment Type*
Arguments for
Command or
Response to
Query
1 byte
Command only.
Soft Reboots the unit in the form x where:
x = 1 (Reboot System)
45 bytes
Query only.
Returns the configuration status of the unit in detailed format, where:
ATT= attenuation in dB
AMP=RF power amplifier state where 0=OFF, 1 = ON
MUT=RF mute state where 0=Unmuted, 1 = Muted
ONL= Online status for redundancy (NOT USED)
RED=Redundancy mode (NOT USED)
ESW=Redundancy state and mode (NOT USED)
AOF=Attenuator Offset in dB (NOT USED)
AFR= Auto fault recovery where 0=Manual, 1=Auto
XRF=External reference status: N/A=no external reference; 05M=5 MHz; 10M=10 MHz (NOT USED)
EXAMPLE: <0001/RCS?{CR}
>0001/RCS={CR}
RCS={CR}
ATT=12.75{CR}
AMP=1{CR}
MUT=1{CR}
ONL=1{CR} (NOT USED)
RED=0{CR} (NOT USED)
ESW=X{CR} (NOT USED)
AOF=XXXXX{CR} (NOT USED)
AFR=1{CR}
XRF=N/A (NOT USED) {CR}{LF}
22 bytes
Query only.
Returns the Model Number and the installed M&C firmware version.
EXAMPLE: <0001/RET?{CR}
>0001/RET=CPA-300 VER: 1.0.3{CR}{LF}
Description of Arguments
(Note that all arguments are ASCII numeric codes from 48 to 57)
5–18
MN-LPODR
Revision 3
Target-to-Controller
(see Description of Arguments)
Response to
Response to
Command
Query
RBT =
RBT=x
RBT?
RBT*
RCS=
RCS=x....x
RET=
RET=x....x