Extron electronics DXP DVI Pro User Manual page 51

Digital matrix switchers
Hide thumbs Also See for DXP DVI Pro:
Table of Contents

Advertisement

To perform a soft reset of the switcher:
1.
Use a small Philips screwdriver to press and hold the rear panel Reset button until
the front panel Video and Audio buttons blink once (for an events reset), twice (for a
system reset), or three times (for an absolute reset).
Press and hold
Reset LED blinks once.
the Reset button.
3 seconds
Events Reset
(Mode 3)
Front panel I/O buttons blink once.
Press and hold
the Reset button.
6 seconds
IP Settings
Reset
(Mode 4)
Front panel I/O buttons blink twice.
Press and hold
the Reset button.
9 seconds
Absolute Reset
(Mode 5)
Front panel I/O buttons blink three times.
Figure 61.
Soft Resets
2.
Release the Reset button and then immediately press and release the Reset
button again. Nothing happens if the second momentary press does not occur within
1 second.
Release, then immediately
press and release again.
I / O
VIDEO
AUDIO
Release, then immediately
Reset LED blinks twice.
press and release again.
I / O
AUDIO
VIDEO
Reset LED blinks
Release, then immediately
three times.
press and release again.
I / O
VIDEO
AUDIO
DXP DVI Pro and DXP HDMI Series • Operation
43

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dxp hdmi

Table of Contents