DTP T DSW 4K Series • Setup Guide This setup guide provides instructions for an experienced installer to set up and operate the Extron DTP T DSW 4K series of twisted pair (TP) switchers. Extron IN1608 DTP T DSW 4K 333 Switcher INPUTS INPUTS OUTPUTS...
Page 2
DTP T DSW 4K Series • Setup Guide (Continued) NOTE: The following descriptions refer to figure 2 on the previous page. DC Power connector — Wire and plug the included external 12 VDC 1.5 A power supply into this 2-pole connector. The DTP T DSW 4K series can provide remote power to a compatible receiver (see the DTP T DSW 4K Series User Guide for wiring and remote power information).
Page 3
The DTP T DSW 4K 233 can transmit video, control, and audio (if applicable) signals up to 230 feet (70 meters). • The DTP T DSW 4K 333 can transmit video, control, and audio (if applicable) signals up to 330 feet (100 meters). For optimal performance, Extron highly recommends the following: RJ-45 termination with STP cable must comply with TIA/EIA-T568B wiring standard for all connections.