9000 hex
Port1 IO-Link Device Information Area
Sub-index 0: Number of entries
Range: −
Size: 1 byte (U8)
Sub-index 4: Device ID
Range: 00000000 to 00FFFFFF hex
Size: 4 bytes (U32)
Sub-index 5: Vendor ID
Range: 00000000 to 0000FFFF hex
Size: 4 bytes (U32)
Sub-index 20: IO-Link Revision
Range: 00 to FF hex
Size: 1 byte (U8)
Sub-index 22: Cycle Time
Range: 00 to FF hex
Size: 1 byte (U8)
Sub-index 24: Process Data In Length
Range: 00 to 20 hex
Size: 1 byte (U8)
Sub-index 25: Process Data Out Length
Range: 00 to 20 hex
Size: 1 byte (U8)
9070 hex
Port8 IO-Link Device Information Area
Sub-index 0: Number of entries
Range: −
Size: 1 byte (U8)
Sub-index 4: Device ID
Range: 00000000 to 00FFFFFF hex
Size: 4 bytes (U32)
Sub-index 5: Vendor ID
Range: 00000000 to 0000FFFF hex
Size: 4 bytes (U32)
Sub-index 20: IO-Link Revision
Range: 00 to FF hex
Size: 1 byte (U8)
Sub-index 22: Cycle Time
Range: 00 to FF hex
Size: 1 byte (U8)
Sub-index 24: Process Data In Length
Range: 00 to 20 hex
Size: 1 byte (U8)
Sub-index 25: Process Data Out Length
Range: 00 to 20 hex
Size: 1 byte (U8)
*1 Indexes 9010 hex, 9020 hex, 9030 hex, 9040 hex, 9050 hex, and 9060 hex are intentionally omitted from this
table. Port numbers in each object name of the indexes 9000 hex to 9060 hex are assigned in order from port 2
to port 7, in ascending order. The data definitions, except for the object names, are the same as those for
indexes 9000 hex and 9070 hex.
GX-series EtherCAT Slave Unit User's Manual
Unit: −
Default: 25 hex
Access: RO
Unit: −
Default: 00000000 hex
Access: RO
Unit: −
Default: 00000000 hex
Access: RO
Unit: −
Default: 00 hex
Access: RO
Unit: −
Default: 00 hex
Access: RO
Unit: −
Default: 02 hex
Access: RO
Unit: −
Default: 02 hex
Access: RO
*1
· · ·
Unit: −
Default: 25 hex
Access: RO
Unit: −
Default: 00000000 hex
Access: RO
Unit: −
Default: 00000000 hex
Access: RO
Unit: −
Default: 00 hex
Access: RO
Unit: −
Default: 00 hex
Access: RO
Unit: −
Default: 02 hex
Access: RO
Unit: −
Default: 02 hex
Access: RO
A Appendix
Attribute: −
PDO map: Not possible
Attribute: −
PDO map: Not possible
Attribute: −
PDO map: Not possible
Attribute: −
PDO map: Not possible
Attribute: −
PDO map: Not possible
Attribute: −
PDO map: Not possible
Attribute: −
PDO map: Not possible
Attribute: −
PDO map: Not possible
Attribute: −
PDO map: Not possible
Attribute: −
PDO map: Not possible