Platform Controls; Controllers; Boom Function Speed Controller Adjustments - Genie Z-34/22 Service Manual

Bi-energy power
Hide thumbs Also See for Z-34/22:
Table of Contents

Advertisement

April 2016
1-1

Controllers

Platform Controls

The drive joystick is connected to the drive motor
controller located under the non-steer end drive
chassis cover. The drive motor controller can also
recognize machine drive malfunctions and display
controller fault codes by flashing a LED at the
ground controls. See the Troubleshooting section
of this manual for a list of fault codes and additional
information. There are no adjustments needed on
the drive joystick controller. For further information
or assistance, contact the Genie Product Support.
1 boom function speed controller
2 drive joystick
Part No. 139234
Boom F unction Speed Contr oller Adj ustm ents
Boom Function Speed Controller
Adjustments
Note: Do not adjust the boom function speed
controller unless the static battery supply voltage is
above 24V DC.
1
Turn the key switch to platform controls and
pull out the red Emergency Stop button to the
on position at both the ground and platform
controls.
2
Open the platform control box lid and locate
the boom function speed controller.
1 black/red wire
2 diode
3 white/red wire
4 boom function speed controller
5 ramp rate trimpot
6 threshold trimpot
7 max out trimpot
Z-34/22 Bi-Energy
Service Manual
Platform Controls
Electrocution/burn hazard.
Contact with electrically charged
circuits could result in death or
serious injury. Remove all rings,
watches and other jewelry.
57

Advertisement

Table of Contents
loading

Table of Contents