November 2003
REV A
B-23
Perform Engine Maintenance -
Ford Models
Ford engine specifications require
that this procedure be performed
every 400 hours.
Proper engine maintenance, following the engine
manufacturer's maintenance schedule, is essential
to good engine performance and service life. Failure
to perform the maintenance procedures can lead to
poor engine performance and component damage.
Required maintenance procedures and additional
engine information are available in the
Ford LRG-425 EFI Operator Handbook
(Ford part number FPP 194-302).
Ford LRG-425 EFI Operator Handbook
Genie part number
To access the engine:
1 Remove the two engine pivot plate retaining
bolts. Swing the engine pivot plate out away
from the machine and secure it from moving.
Crushing hazard. Failure to secure
the engine pivot plate from moving
could result in death or serious
injury.
Part No. 75861
Section 3 • Scheduled Maintenance Procedures
77831
Genie Z-60/34
CHECKLIST B PROCEDURES
3 - 35