Section 3 • Scheduled Maintenance Procedures
CHECKLIST C PROCEDURES
6 Add an additional 75 lbs./34 kg to the original
test weight to overload the platform based on
your maximum platform capacity:
Result: The alarm should be sounding.
The platform overload indicator light should be
flashing at both the ground and platform
controls.
If the alarm does not sound and
the platform overload indicator light
does not come on with the test
weights in any of the platform
locations, the platform overload
system needs to be calibrated.
See D-6, How to Calibrate the
Platform Overload System.
There may be an approximate 2
second delay before the overload
indicator light turns on and the
alarm sounds.
3 - 38
7 Carefully move the test weights to each
remaining location in the platform.
Result: The alarm should be sounding.
The platform overload indicator light should be
flashing at both the ground and platform
controls.
8 Test all machine functions from the platform
controls.
Result: All platform control functions should not
operate.
9 Turn the key switch to ground control.
Genie Z-60/34
November 2003
If the alarm does not sound and
the platform overload indicator light
does not come on with the test
weights in any of the platform
locations, the platform overload
system needs to be calibrated.
See D-6, How to Calibrate the
Platform Overload System.
There may be an approximate 2
second delay before the overload
indicator light turns on and the
alarm sounds.
Part No. 75861
REV A