Section 5 • Fault Codes
FAULT CODES
Error Source
ID
Name
Boom 2 flow
33
control valve
Turntable rotate
41
joystick
Turntable rotate
42
directional valves
Turntable rotate
43
flow control valve
Drive enable
44
override switches
5 - 4
Error Type
ID
Name
12
Value too high
15
Value too low
17
Not calibrated
18
Just calibrated
11
Value at 5V
12
Value too high
15
Value too low
16
Value at 0V
17
Not calibrated
18
Just calibrated
21
Fault
12
Value too high
15
Value too low
17
Not calibrated
18
Just calibrated
21
Fault
Genie Z-60/34
Condition
Limited speed and
direction frozen at
zero and neutral.
Alarm sounds
indicating fault.
Normal function
except threshold for
one or both directions
is zero.
Limited speed and
direction frozen at
zero and neutral.
Alarm sounds
indicating fault.
Joystick speed and
direction frozen at
zero and neutral.
Initiate 1-second beep
of alarm.
Limited speed and
direction frozen at
zero and neutral.
Alarm sounds
indicating fault.
Limited speed and
direction frozen at
zero and neutral.
Alarm sounds
indicating fault.
Normal function
except threshold for
one or both directions
is zero.
Enable override
direction is frozen at
neutral.
November 2003
REV A
Solution
Power up
controller with
problem corrected.
Calibrate valve
thresholds.
Self-clearing.
(transient)
Power up
controller with
problem corrected.
Calibrate joystick.
Self-clearing.
(transient)
Power up
controller with
problem corrected.
Power up
controller with
problem corrected.
Calibrate valve
thresholds.
Self-clearing.
(transient)
Power up
controller with
problem corrected.