Genie Z-60/34 Service Manual page 139

Hide thumbs Also See for Z-60/34:
Table of Contents

Advertisement

November 2003
REV A
Error Source
ID
Name
Boom 1 Joystick
21
(primary boom up/
down)
Boom 1 directional
22
valves
Boom 1 flow
23
control valve
Boom 2 Joystick
31
(secondary boom
up/down or
primary boom
extend/retract)
Boom 2 directional
32
valves
Part No. 75861
Error Type
ID
Name
11
Value at 5V
12
Value too high
15
Value too low
16
Value at 0V
17
Not calibrated
18
Just calibrated
21
Fault
12
Value too high
15
Value too low
17
Not calibrated
18
Just calibrated
11
Value at 5V
12
Value too high
15
Value too low
16
Value at 0V
17
Not calibrated
18
Just calibrated
21
Fault
Genie Z-60/34
Condition
Limited speed and
direction frozen at
zero and neutral.
Alarm sounds
indicating fault.
Joystick speed and
direction frozen at
zero and neutral.
Initiate 1-second beep
of alarm.
Limited speed and
direction frozen at
zero and neutral.
Alarm sounds
indicating fault.
Limited speed and
direction frozen at
zero and neutral.
Alarm sounds
indicating fault.
Normal function
except threshold for
one or both directions
is zero.
Limited speed and
direction frozen at
zero and neutral.
Alarm sounds
indicating fault.
Joystick speed and
direction frozen at
zero and neutral.
Initiate 1 second beep
of alarm.
Limited speed and
direction frozen at
zero and neutral.
Alarm sounds
indicating fault.
Section 5 • Fault Codes
FAULT CODES
Solution
Power up
controller with
problem corrected.
Calibrate joystick.
Self-clearing.
(transient)
Power up
controller with
problem corrected.
Power up
controller with
problem corrected.
Calibrate valve
thresholds.
Self-clearing.
(transient)
Power up
controller with
problem corrected.
Calibrate joystick.
Self-clearing.
(transient)
Power up
controller with
problem corrected.
Continued on next page
5 - 3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents