Genie Z-60/34 Service Manual page 83

Hide thumbs Also See for Z-60/34:
Table of Contents

Advertisement

November 2003
REV A
4 Activate auxiliary power and hold the platform
rotate toggle switch to the left position until the
platform is fully rotated to the left. Continue
holding the toggle switch until air stops coming
out of the bleed valve. Close the bleed valve.
Crushing hazard. Keep clear of
the platform during rotation.
5 Connect the clear hose to the bottom bleed
valve and open the valve. Do not remove the
bleed valve.
6 Activate auxiliary power and hold the platform
rotate toggle switch to the right position until the
platform is fully rotated to the right. Continue
holding the toggle switch until air stops coming
out of the bleed valve. Close the bleed valve.
Crushing hazard. Keep clear of
the platform during rotation.
7 Remove the hose from the bleed valve and
clean up any hydraulic oil that may have spilled.
8 Rotate the platform fully in both directions and
inspect the bleed valves for leaks.