Figure 340 VPN > VPN Settings > VPN Policies
Go to SonicWALL VPN > VPN Settings > Currently Active VPN Tunnels > VPN Tunnel Statics
4
to check Tunnel valid time, Bytes In (Incoming Data) and Bytes Out (Outgoing Data).
Figure 341 VPN > VPN Settings > Currently Active VPN Tunnels
To test whether or not a tunnel is working, ping from a computer at one site to a computer at the
5
other. Ensure that both computers have Internet access (via the IPSec devices).
Figure 342 PC behind ZyWALL/USG > Window 7 > cmd > ping 192.168.168.33
Figure 343 PC behind SonicWALL> Window 7 > cmd > ping 192.168.1.33

4.6.4 What Can Go Wrong?

If you see below [info] or [error] log message, please check ZyWALL/USG Phase 1 Settings. Both
1
ZyWALL/USG and SonicWALL must use the same Pre-Shared Key, Encryption, Authentication
method, DH key group and ID Type to establish the IKE SA.
Chapter 4 Create Site-to-Site VPN Tunnels
ZyWALL/USG Series User's Guide