2.3 Setting Measurement Conditions

Setting Measurement Conditions
Here describes how to set the measurement conditions on the channel
setting window and the condition setting panel.
Pressing the {CH} button on the Main screen opens the channel setting
window. Fig. 2-4 shows the typical display example of the channel setting
window. On this window, data type for measurement at each channel,
measurement target axis, and measurement interval of each data can be
set.
Fig. 2-4: Channel Setting Window
 Sampling time
Sets the sampling interval of the data to be acquired. Settable options
are 4.0, 8.0, 16.0, 32.0, and 64.0 [ms], each of which corresponds to
the sampling frequencies of 250, 125, 62.5, 31.25, and 15.625 [Hz],
respectively.
 Measurement valid/invalid check box
Requires setting for each channel, where the channel with a check
mark becomes valid for measurement.
When the multiple channels are to be valid, the channel numbers are
not necessarily to be sequential.
The more the channels are available, the more the process
is overloaded, and it affect the data updating speed in the
NOTE
waveform display area; it is recommended that
unnecessary channels, if any, should be set to invalid.
2-4
165467-1CD
HW1481803
16 of 48