Saving and Loading the Measurement Data

3.1
3.1.1 Data File Name and Save Destination
3
Saving and Loading the Measurement Data
3.1 SaveMode Setting Panel
This chapter describes the saving and loading of the measurement data.
SaveMode Setting Panel
With the data measurement stopped, select (touch) {Save} tab in the
condition setting panel. Fig. 3-1 shows the typical example of SaveMode
setting on the panel.
Fig. 3-1: SaveMode Setting Panel
 SaveMode
Enables to select Manual/Auto of the saving mode. In selecting the
automatic saving mode {Auto}, ensure to perform the setting with the
external CF or USB memory inserted to the Programming Pendant.
Automatic save mode
The automatic save function works only when the trigger
NOTE
mode is valid.
The data is saved when the trigger conditions are satisfied
and the measurement is completed.
 {HardCopy} button
Pressing the button enables to save the hard copy of the screen in CF
or USB memory.
 {SaveCSV} button
It is available only when {Manual} is selected for the SaveMode option.
Pressing the button enables saving the measurement data into CF or
USB memory.
The measurement data is saved in the CSV (Comma Separated Value)
file format.
The file is automatically given a file name consisting of the time, date and
the year when the save operation starts (yyyymmdd_hhmmss.csv).
As the CSV file destination, a folder of the following address is
automatically created in the external CF or USB memory of the pendant,
and the data is saved in the folder:
¥
PP_OSCILLOSCOPE
The hard copy data of the screen is saved in the JPG (Joint Photographic
Experts Group) format.