Pendant Oscilloscope
Function
6
Error Messages
Table 6-1: Error Messages and Countermeasures of PP Oscilloscope
(Sheet 2 of 2)
Error messages
The acceptable delaying range of
graph drawing exceeded. Implement
any of the following countermeasures.
- Set slower sampling time.
- Decrease the number of available
channels.
- Set shorter value for Time Scale
setting. (Shorten the data length.)
No corresponding data exists within
the zoom range.
Cannot recognize Flash Memory.
Setting for SaveMode is switched
from Auto to Manual.
Cannot recognize Flash Memory.
SaveMode is switched from Auto to
Manual.
Perform manual saving if necessary.
Failed in saving CSV file.
Perform manual saving if necessary.
Not enough disk space.
Make room for the file to perform
manual saving.
File format is not correct.
Failed in loading CSV file.
File not specified.
Specified file not exist.
Failed in starting measurement.
Failed in obtaining measured
value.[**]
Measurement is canceled.
(**: numerical value)
Failed in completing measurement.
6-2
Countermeasures
Process time for graph drawing is not
enough for the volume of measurement
data.
Set a slower sampling time, decrease the
available channel number, or set shorter
timescale value.
There is no measurement data within the
zoom range currently specified. Set the
zoom range again.
Insert CF or USB memory and set
SaveMode again.
Flash memory could not be recognized
at data save.
Insert CF or USB memory and retry data
saving manually.
An error has occurred in flash memory.
Try CF or USB memory insertion again
or replacement, and retry data saving
manually.
Assure enough disk space for CF or USB
memory.
The file to load has not been matched
with the data format of PP oscilloscope.
Check if the file has been correctly
saved.
The file to load has been found not to be
the correct file for the PP oscilloscope.
The file cannot be loaded.
Specify the file to load.
The specified file does not exist on the
CF or USB memory.
An error has occurred at measurement
start, and the measurement cannot be
started. Retry the measurement.
If the alarm persists, terminate the
pendant oscilloscope application, and
restart the application.
An error was found in the acquired
measurement data.
The system is forcefully turned into the
measurement stop condition. Retry the
measurement.
If the alarm persists, terminate the
pendant oscilloscope application, and
restart the application.
The measurement process has not been
correctly completed.
Terminate the pendant oscilloscope
application, and restart the application.