Pendant Oscilloscope
Function
2
Setting and Operation for Data Measurement
2.3 Setting Measurement Conditions
TrgType (Trigger type)
Select the trigger type to use. Selectable options are Up, Down,
Up&Down, and Alarm.
When selecting Alarm, some of the setting parameters of Trigger
Conditions are changed.
Table 2-2: Characteristics of Trigger Type
Trigger type
Trigger condition
Up
When the trigger target channel data exceeds the trigger level
Down
When the trigger target channel data falls below the trigger level
Up&Down
When the trigger target channel data is either over or below the
trigger level
Alarm
When the alarm assigned to alarm number occurs
PreTrg (Pre-trigger)
Specify the pre-trigger position by the horizontal axis division
(0 to 10.0).
Current pre-trigger position is shown by a marker on the upper part of
the waveform display area (see Fig. 2-10).
Fig. 2-10: Pre-trigger Marker
2-12
165467-1CD
Pre-trigger
maeker
HW1481803