Pendant Oscilloscope
Function
2.3.3 TimeScale Setting Panel
2
Setting and Operation for Data Measurement
2.3 Setting Measurement Conditions
With the data measurement stopped, touch {TimeScale} tab on the
condition setting panel. Fig. 2-7 shows the typical display example of
TimeScale setting panel.
Fig. 2-7: TimeScale Setting Panel
ms/div
Sets the time for the horizontal axis of the waveform display area. The
value selected here should be the time width [ms] per division of
horizontal axis. Since there are 10 divisions in the entire horizontal
axis, the eventual data length is 10 times of the specified value.
Selectable range of ms/div depends on the combination of sampling
time set on the Channel Setting window:
With the sampling time of 4 [ms]:
With the sampling time of 8 [ms] or more:
2-10
Up to 5000 [ms/div] (data length: 50 [s])
Up to 10000 [ms/div] (data length: 100 [s])
HW1481803
165467-1CD
22 of 48