Trigger Mode - YASKAWA DX200 Instructions Manual

Options instructions for pendant oscilloscope function
Hide thumbs Also See for DX200:
Table of Contents

Advertisement

Pendant Oscilloscope
Function

2.4.2 Trigger Mode

2
Setting and Operation for Data Measurement
2.4 Starting and Ending Measurement
The Trigger mode automatically stops the measurement when the trigger
condition is satisfied, and displays the waveform on the screen. Follow
the step below:
1. Set the trigger conditions on the Trigger setting panel.
2. Select ON for {TriggerMode}.
3. Start the measurement by the {START} button. This starts the data
measurement, and the waveform display area is turned to the waiting
state, and holds the state until the trigger condition is satisfied. On the
screen, a message "Waiting for trigger..." is displayed (see Fig. 2-14).
To cancel the measurement during this state, press the {STOP} button.
Fig. 2-14: Display of Trigger Mode "Waiting for trigger"
4. When the trigger condition is satisfied, "Triggered" is displayed on the
screen (see Fig. 2-15). To collect the waveform data later than the
trigger position, the condition is held for as long as 100 seconds
according to the setting of data length and pre-trigger. To cancel the
measurement during this state, press the {STOP} button.
Fig. 2-15: Display of Trigger Mode "Triggered"
5. When all the waveform data for an entire window is acquired, the
measurement automatically ends and the waveform is displayed.
2-16
165467-1CD
HW1481803
28 of 48