Pendant Oscilloscope
Function
4
Other Functions
4.4 Operation Function by Dedicated Input
51172: Pendant Oscilloscope IO Acceptance Ready
Notifies that PP oscilloscope is monitoring the start request
State
(40761) and the CSV file saving request (40762).
Only when the following conditions are satisfied, this signal is
turned ON.
• Measurement CH settings are completed.
• Not under measurement.
SUPPLE-
MENT
• Not under saving the CSV file.
• Not in the minimized status.
• Not under zooming (section 4.1.1 "During Execution of
Zoom Function" on page 4-2).
51173: Pendant Oscilloscope Measurement Error
Notifies that the measurement failed to start when the {START}
State
button or the start requesting signal (40761) tried to start
measurement.
Check that there are no errors in the measurement conditions.
This signal is turned OFF when newly starting measurement.
51174: Pendant Oscilloscope CSV File Under Saving
Notifies that the CSV file is under saving.
State
51175: Pendant Oscilloscope CSV File Error in Saving
Notifies that saving is failed when starting saving with the {Save
State
CSV} button or the CSV file saving requesting signal (40762).
Check the condition of the external storage device.
This signal is turned OFF when newly starting saving.
When requesting saving in the condition that the measurement
is never performed after starting PP oscilloscope, saving is not
performed but this signal is not turned ON.