The pendant oscilloscope can output the messages for confirming the
operation or notifying the process completion. Especially when the data
acquisition error or abnormal setting should occur, the application outputs
error messages such as shown in Fig. 6-1 to notify the problem.
When any error message is displayed, first check the content, touch {OK}
to clear the message, and follow necessary countermeasures.
Fig. 6-1: Example of Error Message
Table 6-1 shows the list of error messages and the countermeasure.
Table 6-1: Error Messages and Countermeasures of PP Oscilloscope
(Sheet 1 of 2)
Error messages
Input the value between ** and **.
The value to ** decimal places can be
input.
Input the numeric value.
(**: numerical value)
The specified number for the alarm
trigger is not correct.
Review the setting.
Any trigger can be detected with this
setting.
Review the trigger level setting.
The axis number which doesn't exist
in the system has been specified.
Review the channel setting.
Input correct I/O number.
Processing time insufficient.
Set slower sampling time or decrease
the number of available channels.
6-1
Countermeasures
The input value is out of the limitation of
input box.
Retry inputting a correct value according
to the error message.
This error can occur in all of the input
boxes.
A non-existent number is specified as the
alarm number of alarm trigger. Retry
setting a correct number.
The trigger level is out of the waveform
display area due to excessively large
trigger level or channels zero position.
Check the trigger level setting.
The axis number which does not exist in
the system is specified to either of axes
in the channel setting window.
Set the correct number.
The concurrent I/O number which does
not exist is specified.
Set the correct number.
Process time for data acquisition is not
enough for the volume of measurement
data.
Set a slower sampling time, or decrease
the available channel number.
HW1481803