2.4 Starting and Ending Measurement

Starting and Ending Measurement
Here describes the step of actual data measurement. Ensure to start the
measurement after completing the condition setting described in section
2.3 "Setting Measurement Conditions" on page 2-4.
The Continuous mode is the mode in which the measurement data is
always displayed and updated in the time-series order. Follow the step
below:
1. Select OFF for {TriggerMode} on the Trigger setting panel.
2. Start the measurement by the {START} button. The data
measurement starts, and the data is displayed in the time-series order
on the waveform display area, and updated in series.
3. When the time passes longer than the specified data length from the
measurement start, the data is discarded from the oldest one, and the
new data is updated in series (see Fig. 2-13).
4. When the target waveform data is displayed on the waveform display
area, press the {STOP} button to stop the measurement.
Fig. 2-13: Continuous Mode
Old data
Continuous mode enables to display the measurement data
in time-series order, but it does not necessarily assure the
real-time display. The data contain a delay to a certain
extent, and the delay can be extended as the measured data
is large in volume.
The following setting changes help for the challenging of
SUPPLE-
MENT
real-time display:
- Trying smaller number of available channels
- Trying longer sampling time
- Trying shorter data length
2-15
Flow of data update
HW1481803
Latest data