2.3.4 Trigger Setting Panel

Trigger level
Zero point of
channel
2
Setting and Operation for Data Measurement
2.3 Setting Measurement Conditions
With the data measurement stopped, select (touch) {Trigger} tab on the
condition setting panel. Fig. 2-8 shows the typical display example of
Trigger setting panel.
This panel allows the setting of trigger function.
Fig. 2-8: Trigger Setting Panel
The trigger function is the function to automatically stop the measurement
and display the waveform at the point where a certain condition is satisfied
during the data measurement.
As trigger conditions, three options are available: when the target channel
data exceeds or falls below the specified value (trigger level), or when any
alarm occurs.
The data stop position is determined by Pre-trigger. The measurement
result is displayed so that the position satisfying the trigger conditions
becomes the Pre-trigger position. For example in Fig. 2-9, the data length
is 10 [s] and the specified Pre-trigger is 3 [div] in horizontal axis. This
allows the setting where the data before the trigger is acquired for 3
seconds, and the data after the trigger is acquired for 7 seconds.
Fig. 2-9: Outline of Trigger Function
Pre-trigger
Data before Trigger 3[s]
 CH
Select the channel as trigger target. Only the valid channel is
selectable.
2-11
Data length
Data after Trigger 7[s]
Horizontal axis
HW1481803
Zero point of
waveform display
23 of 48