Pendant Oscilloscope
Function

2.3.2 CH Display Setting Panel

2
Setting and Operation for Data Measurement
2.3 Setting Measurement Conditions
With the data measurement stopped, select (touch) the {ChCondition} tab
on the condition setting panel. Fig. 2-5 shows the typical display example
of the CH display setting panel.
Fig. 2-5: ChCondition Setting Panel
This panel allows the setting of panel display targeted to the channels
validated in the channel setting window.
 Channel
Select the target channel for setting operation. Upon the channels set
here, the setting change given to the following options  to  is
reflected.
Note that the invalid channels are disabled (in which the radio button is
inoperable), and cannot be selected.
 Display
Enables to select either to display {ON} or hide {OFF} the waveform
data of target channel. The data is internally stored even when the data
is measured with the Display {OFF}, and the corresponding waveform
data is displayed when Display {ON} is selected.
 Invert
Enables to select either to invert the waveform data of target channel or
not. Selecting Invert {ON} inverts the display of waveform data in a
waveform display area between positive and negative. Selecting Invert
{OFF} returns to the original state.
2-8
165467-1CD
HW1481803
20 of 48