4.2 Cursor Measurement Function

Cursor Measurement Function
With the data measurement stopped, select (touch) the {Measure} tab on
the condition setting panel. Fig. 4-3 shows the typical example of the
Measure panel.
Fig. 4-3: Measure Panel and Cursor Display (with Vertical Cursor)
Measurement
parameters
The cursor measurement function is the function to read the data within
the range selected by two cursors, calculate the values corresponding to
the specified measurement parameters, and display the result.
 CursorType
Select the cursor type either from Horizontal or Vertical. Select the type
according to the usage. The {OFF} option makes the function
unavailable.
 CH
Specify the channel to which the cursor measurement is targeted. The
channel specified as unavailable in the Channel Setting window cannot
be selected.
 Cursor1, Cursor2
When the vertical cursor is selected in , specify the cursor position in
the horizontal division (0 to 10.0).
When the horizontal cursor is selected in , specify it in the vertical
division (-5.0 to 5.0).
The area enclosed by Cursor1 and Cursor2 becomes the target area of
cursor measurement. Even when the positions of Cursor1 and Cursor2
are switched, the target area is always the area inside these two lines.
4-3
Cursor
4
35 of 48
HW1481803