Pendant Oscilloscope
Function
4.4
4.4.1 Dedicated Input Signal
40767
40766
40765
SIN#608
SIN#607
SIN#606
4
Other Functions

4.4 Operation Function by Dedicated Input

Operation Function by Dedicated Input
When "1" is set to S2C1244, the signal operation function is enabled.
This function makes the following operations performed on the
programming pendant executable externally by the dedicated input
signals.
• Starting PP oscilloscope
• Starting measurement
• Saving CSV file
Also, the PP oscilloscope status is output to the dedicated output signal,
and it can be externally referred.
The operation function by dedicated input is available in the
NOTE
version DN1.61.00A(--)-00 and the later.
This function aims to start measurement externally without
operating and referring to the programming pendant.
NOTE
Therefore, it has no dedicated input signal to stop
measurement.
For stopping measurement, use the trigger mode.
40764
40763
SIN#605
SIN#604
40760: Starting Pendant Oscilloscope
Starts PP oscilloscope.
Rising
When PP oscilloscope is in minimized status, it is released.
This signal performs the same operation as the operation when
pressing {Robot}
When it is in one of the following status, pendant
oscilloscope cannot be started even if this signal is turned
ON.
NOTE
After releasing the status, turn ON this signal.
• An error exists.
• Other external application is running.
4-8
40762
40761
SIN#603
SIN#602
OSC
OSC
SAVE START
MEAS.START
{Pendant oscilloscope} from the main menu.
HW1481803
165467-1CD
40760
SIN#601
OSC
STARTUP
40 of 48