Supporting procedures
High Temperature Troubleshooting
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
Replace the card. See
6
repair process in the Customer and Product Support guide to return the faulty card to an
authorized repair center for replacement.
E
N D
O F
...................................................................................................................................................................................................
Changing the Equipment Controller Configuration
in an NE
Changing an NE from a Nonredundant to a Redundant
Equipment Controller Configuration
Before you begin
Before you can change a NE from a nonredundant to a redundant Equipment Controller
configuration, you must ensure that the following conditions are met:
• No unacknowledged alarms exist on the NE.
• The NE is not in the process of completing a software upgrade.
• The NE is not in the process of completing a database backup or restore.
• Ensure that the Equipment Controller you plan to insert for this procedure, is
approved for duplex controller configurations (Alcatel-Lucent Part Number (APN) =
8DG59241AB).
This procedure must be performed on the main shelf of a NE with one universal shelf.
Note: If you pre-provision the redundant Equipment Controller, an alarm is raised to
indicate that the card is missing. Once you install the redundant Equipment
Controller, the alarm is cleared.
To perform this procedure using the WebUI, go to
Nonredundant to a Redundant Equipment Controller configuration Using the WebUI"
(p.
3-72).
To perform this procedure using the CLI, go to
a Redundant Equipment Controller Configuration Using the CLI" (p.
....................................................................................................................................................................................................................................
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
"Replacing System Components" (p.
S T E P S
High Temperature Threshold Exceeded
3-20). Follow the return and
"Changing an NE from a
"Changing an NE from a Nonredundant to
3-72).
3-71