Trouble-clearing procedures
SDEG-O
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
Replace the card. Refer to
9
and repair process in the Customer and Product Support guide to return the faulty card to
an authorized repair center for replacement.
E
N D
O F
...................................................................................................................................................................................................
SDEGR
SDEGR (Egress Signal Degrade - ODU)
The OT port has detected a Signal Degrade Bit Error Rate exiting the OT client port.
Severity
Service affecting?
Applicability
Corrective Action
This procedure details the corrective action for clearing the SDBER against the OT port.
...................................................................................................................................................................................................
Retrieve power level reading on the local port.
1
...................................................................................................................................................................................................
2
Clean the fiber.
...................................................................................................................................................................................................
If cleaning the fiber does not clear the problem, replace the fiber.
3
...................................................................................................................................................................................................
4
If the power level is within the operating range, check for pluggable module alarms.
...................................................................................................................................................................................................
Replace the pluggable module.
5