Alcatel-Lucent 1830 PSS-16 Maintenance And Trouble-Clearing User Manual page 457

1830 pss series photonic service switch
Table of Contents

Advertisement

Trouble-clearing procedures
NTPOOSYNC
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
Reseat the Equipment Controller that is raising the NTPOOSYNC condition.
4
...................................................................................................................................................................................................
5
Replace the Equipment Controller that is raising the NTPOOSYNC condition. Follow the
return and repair process to return the card to an authorized repair center for replacement.
E
N D
O F
...................................................................................................................................................................................................
OAPUMPBIASCURRHIGH
OAPUMPBIASCURRHIGH (OA pump laser bias current high)
The OT port has detected Modulator output power out of range.
Severity
Service affecting?
Applicability
Corrective Action
A cold reset, reseat, or replacement of a card is service impacting if the card is currently
carrying services. To determine if any services are currently carried over a card, perform
the procedure
If there are services currently carried over the card, it may be best to wait for a
maintenance window before resetting, replacing, or reseating the card.
This procedure details the corrective action for an OAPUMPBIASCURRHIGH against
the LD pack.
...................................................................................................................................................................................................
If another card failure is reported on the card, follow the procedure for that specific alarm.
1
E
N D
O F
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
S T E P S
Major
No
AHPHG, AHPLG, ALPHG, A2325A, AM2125A, AM2125B,
MESH4, RA2P
NOTICE
Service-disruption hazard
"Reseating a Card" (p.
S T E P S
NTPOOSYNC (Network Time Protocol is enabled, but no NTP
3-19).
server is reachable)
2-207