Trouble-clearing procedures
PWRADJFAIL
....................................................................................................................................................................................................................................
WEBUI
...................................................................................................................................................................................................
9
If...
the power levels are within the acceptable
limits,
the power levels are not within the acceptable
limits,
...................................................................................................................................................................................................
10
CLI
...................................................................................................................................................................................................
Using the standard optical fiber jumper cleaning procedure, clean the fiber, and measure
11
the power again. Clean the receive bulkhead connector on the card. If the cleaning/fiber
un-kinking resolves the power levels to the acceptable limits, then go back to
...................................................................................................................................................................................................
Verify that the fiber length and type used in the span immediately upstream of the
12
alarmed card still match the original specifications according to the network plan. Any
deviation from the specifications, as a result of work done on the span, may require new
network parameters and /or a rebalancing of the network to compensate. Follow the
appropriate procedures in the Alcatel-Lucent User Provisioning Guide to validate the new
parameters of the network.
...................................................................................................................................................................................................
13
Perform the
PWRADJFAIL alarm and fix these first.
...................................................................................................................................................................................................
Perform a warm reset on the card where the PWRADJFAIL alarm is raised.
14
CLI
WEBUI
....................................................................................................................................................................................................................................
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
From the Equipment Tree, select the card, and select the desired port.
Click the Wave Keys In/Wave Keys Out tab.
config powermgmt
"Path Power Trace" (p. 3-8)
card type shelf slot
config card
Select the card, click the
PWRADJFAIL (Power Adjustment Failure)
Then...
perform a power adjust operation at the ingress
Amplifier card or the ALPHG card that has
raised the PWRADJFAIL alarm (continue
withStep
10).
check for kinking of the fiber at various points
upstream of the receive connector on the
alarmed card. Proceed to
ingress | egress shelf slot
to determine other possible causes of the
reset warm
tab, select
Reboot
Warm Reboot
Step
11.
adjust
Step
9.
>
.
Submit
2-261