Alcatel-Lucent 1830 PSS-16 Maintenance And Trouble-Clearing User Manual page 493

1830 pss series photonic service switch
Table of Contents

Advertisement

Trouble-clearing procedures
OPRUNACHIEVE
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
If the output power is with acceptable limits, clean and reconnect the transponder and OT
4
or SVAC and check the alarm status of the shelf. If the output power remains below
specification:
1. Reseat the transponder card. Refer to
2. Measure the optical output power of the transponder. If the output power remains
below specification, Replace the card. Refer to
(p.
guide to return the faulty card to an authorized repair center for replacement.
3. If the source transponder for the signal is outside the 1830 PSS (alien channel
transport case) replace the source transponder.
4. If the source optical interface is a replaceable pluggable optical module, replace the
SFP or XFP module (see
Module" (p.
...................................................................................................................................................................................................
5
If the encoder is an OT (VA, SVAC or MVAC) port, using an optical power meter,
measure the optical power being received.
If...
the loss over the fiber between the transponder
and OT VA/SVAC/MVAC port is reasonable,
the loss over the fiber between the transponder
and OT VA/SVAC/MVAC port is higher than
expected,
...................................................................................................................................................................................................
Measure the optical power being received at the OT VA, SVAC or MVAC In port.
6
If...
the loss over the fiber between the transponder
and OT VA/SVAC/MVAC port is reasonable,
the loss over the fiber between the transponder
and OT VA/SVAC/MVAC port is higher than
expected,
...................................................................................................................................................................................................
Clean the OT VA, SVAC or MVAC In port. Clean and reconnect the fiber between the
7
transponder and OT VA, SVAC or MVAC port. Check the alarm status of the shelf.
....................................................................................................................................................................................................................................
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
3-20). Follow the return and repair process in the Customer and Product Support
3-30)).
"Reseating a Card" (p.
"Replacing an SFP Module" (p. 3-27)
Then...
continue with
clean, inspect and connect the fiber between
the transponder and OT VA/SVAC/MVAC
port.
Then...
clean and reconnect the transponder and OT
VA/SVAC/MVAC port and check the alarm
status of the shelf.
replace the fiber.
OPRUNACHIEVE (Channel Power Unachievable)
3-19).
"Replacing System Components"
or
"Replacing an XFP
Step
7.
2-243

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1830 pss-321830 pss-361830 pss-4

Table of Contents