Alcatel-Lucent 1830 PSS-16 Maintenance And Trouble-Clearing User Manual page 531

1830 pss series photonic service switch
Table of Contents

Advertisement

Trouble-clearing procedures
REPLUNITMISS
....................................................................................................................................................................................................................................
REPLUNITMISS
REPLUNTMISS (Card Missing)
The card missing condition is raised when a provisioned slot, that has both a programmed
card-type and an Admin state of In-Service, does not have a card in it. The slot has been
provisioned as such and no card has been inserted, or an inserted In-Service card has been
physically removed from that slot.
Severity
Service affecting?
Applicability
Corrective Action
At the end of each step wait to see if the fault clears. If not, continue with the next step.
...................................................................................................................................................................................................
1
If...
the affected card is a PF in a PSS-16 system,
the affected card is not a PF in a PSS-16
system,
...................................................................................................................................................................................................
Although only one PF is required in the 1830 PSS-16, the REPLUNITMISS condition
2
may occur when only one PF is present. Disable the REPLUNITMISS alarm on the PF
slot that is empty:
CLI
WEBUI
....................................................................................................................................................................................................................................
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
TC
No
All cards
slot
config alm attr
In the Equipment Tree, select
On the Alarmable Conditions window, in the Override Severity column,
select
for the empty PF slot.
Not Reported
Click
.
Submit
REPLUNTMISS (Card Missing)
Then...
continue with
Step
2.
proceed to
Step
3.
and click the
System
Fault
function.
2-281

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1830 pss-321830 pss-361830 pss-4

Table of Contents