Trouble-clearing procedures
OPRLOSSLOW
....................................................................................................................................................................................................................................
Corrective Action
A cold reset, reseat, or replacement of a card is service impacting if the card is currently
carrying services. To determine if any services are currently carried over a card, perform
the procedure
If there are services currently carried over the card, it may be best to wait for a
maintenance window before resetting, replacing, or reseating the card.
At the end of each step wait to see if the fault clears. If not, continue with the next step.
...................................................................................................................................................................................................
1
Retrieve the optical power levels at the DCM port of the amplifier card where the alarm is
raised.
CLI
WEBUI
...................................................................................................................................................................................................
Perform a warm reset on the card where the OPR condition is raised.
2
CLI
WEBUI
...................................................................................................................................................................................................
Perform a cold reset of the card.
3
Note: Refer to Caution at the beginning of this procedure.
CLI
WEBUI
...................................................................................................................................................................................................
Reseat the card. Refer to
4
....................................................................................................................................................................................................................................
2-232
NOTICE
Service-disruption hazard
"Reseating a Card" (p.
show interface <shelf slot port>
From the Equipment Tree, select the card, and select the desired port.
config card
Select the card, click the
config card
Select the card, click the
"Reseating a Card" (p.
OPRLOSSLOW (Out of Operational Range - Loss Too Low)
3-19).
card_type shelf slot
reset warm
Reboot
tab, select
card_type shelf slot
reset cold
Reboot
tab, select
3-19).
Warm Reboot
>
Submit
.
Cold Reboot
>
Submit
.
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011