Trouble-clearing procedures
VCGLOA
....................................................................................................................................................................................................................................
WEBUI
...................................................................................................................................................................................................
3
Perform a cold reset of the card of the far end 11STMM10 that is connected to the
11STMM10 reporting the alarm.
Note: Refer to Caution at the beginning of this procedure.
CLI
WEBUI
...................................................................................................................................................................................................
4
Reseat the card of the far end 11STMM10 that is connected to the 11STMM10 reporting
the alarm. Refer to
...................................................................................................................................................................................................
Replace the 11STMM10 reporting the alarm. Refer to
5
(p.
3-20). Follow the return and repair process in the Customer and Product Support guide
to return the faulty card to an authorized repair center for replacement.
E
N D
O F
...................................................................................................................................................................................................
VCGSSF
VCGSSF (VCG Server Signal Failure)
The OT has detected a VCG Server Signal Failure. This rare condition is raised when the
time slots are incorrect.
Severity
Service affecting?
Applicability
....................................................................................................................................................................................................................................
2-348
Select the card, click the
config card
Select the card, click the
"Reseating a Card" (p.
S T E P S
Critical
Yes
11STMM10
Reboot
tab, select
card_type shelf slot
reset cold
Reboot
tab, select
3-19).
VCGLOA (Loss of alignment)
Warm Reboot
>
Submit
Cold Reboot
>
Submit
"Replacing System Components"
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
.
.