Alcatel-Lucent 1830 PSS-16 Maintenance And Trouble-Clearing User Manual page 467

1830 pss series photonic service switch
Table of Contents

Advertisement

Trouble-clearing procedures
OCHPDI
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
Show the path power trace on the two endpoints of the wavelength service. Determine if
4
the wavelength has achieved the target output power from the transponder. Enter the
following commands on both end points to determine if the launch power has been
achieved.
CLI
WEBUI
...................................................................................................................................................................................................
Ensure that the transponder can provide the required power. If the transponder can
5
provide enough power, clean fiber connectors from the transponder to the OMD or
CWR8 port to ensure the connections are clean.
E
N D
O F
...................................................................................................................................................................................................
OCHKEYDUP
OCHKEYDUP (Duplicate Wave Key)
The NE has detected that another NE in the network is sourcing (heading) an OCh trail
which is using the same wavekeys as one of its own sourced (headed) trails.
The system is designed to prevent this under all normal operating conditions, however,
this situation can happen if the control network was segmented when the OCh trails were
created. If the control network is rejoined and any duplicates are discovered, this alarm
raised. The control network is segmented if the one or more amplifier CN links are down
such that a number of NEs cannot communicate to the remainder of the NEs in the
network.
Having two different OCh trails with the same wavekeys in the same optical network
prevents the ability to distinguish the two OCh trails from each-other with respect to
Wavelength Tracker monitoring capabilities.
Severity
....................................................................................................................................................................................................................................
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
show xc <ID> trace atoz
show xc <ID> trace ztoa
1. Select
Connections
2. Select the desired Cross-Connect.
3. Click
A-Z Trace
S T E P S
Minor
OCHPDI (Channel Payload Defect Indicator)
>
Cross-Connects
.
or
Z-A Trace
.
2-217

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1830 pss-321830 pss-361830 pss-4

Table of Contents