Alcatel-Lucent 1830 PSS-16 Maintenance And Trouble-Clearing User Manual page 375

1830 pss series photonic service switch
Table of Contents

Advertisement

Trouble-clearing procedures
LANRFI
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
Perform a cold reset on the upstream device that is sending the LANRFI condition.
4
Note: Refer to Caution at the beginning of this procedure.
CLI
WEBUI
...................................................................................................................................................................................................
Perform a cold reset on the local card where the LANRFI condition is raised.
5
Note: Refer to Caution at the beginning of this procedure.
...................................................................................................................................................................................................
6
Perform a cold reset on the upstream device that is sending the LANRFI condition
Note: Refer to Caution at the beginning of this procedure.
...................................................................................................................................................................................................
Reseat the local card. If this does not fix the problem, reseat the far-end card.
7
...................................................................................................................................................................................................
Replace the alarmed card. Follow the return and repair process to return the card to an
8
authorized repair center for replacement.
E
N D
O F
...................................................................................................................................................................................................
LASEREOL
LASEREOL (Laser end of life)
The OT port has detected laser end of life.
Severity
Service affecting?
Applicability
....................................................................................................................................................................................................................................
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
config card
Select the card, click the
S T E P S
Major
No
11STAR1
card type shelf slot
reset cold
tab, select
Reboot
LANRFI (Remote Fault Indication)
>
.
Cold Reboot
Submit