Trouble-clearing procedures
LOS
....................................................................................................................................................................................................................................
...................................................................................................................................................................................................
4
If...
no active traffic is present on the system
the optical power is below the required
threshold for the type of pluggable module
installed: LINE Normal Range: -32.0 dBm
(LINE Normal Range)
the optical power is within the required limits
...................................................................................................................................................................................................
5
Perform a warm reset of the card exhibiting the Loss of Signal.
CLI
WEBUI
...................................................................................................................................................................................................
6
Perform a cold reset of the card exhibiting the Loss of Signal.
CLI
WEBUI
Note: Refer to Caution at the beginning of this procedure.
...................................................................................................................................................................................................
7
Reseat the card. Refer to
...................................................................................................................................................................................................
Replace the card. Refer to
8
and repair process in the Customer and Product Support guide to return the faulty card to
an authorized repair center for replacement.
E
N D
O F
...................................................................................................................................................................................................
....................................................................................................................................................................................................................................
2-154
config card
Select the card, click the
config card
Select the card, click the
"Reseating a Card" (p.
"Replacing System Components" (p.
S T E P S
Then...
remove the fiber from the receive port where
the LOS is raised and measure the optical
power.
using the standard optical fiber jumper
cleaning procedure, clean the fiber, and
measure the power again.
clean the receive connector on the card. If the
LOS condition is still present, the problem
may be with the card.
card type shelf slot
reset warm
Reboot
tab, select
card_type shelf slot
Reboot
3-19).
LD Input LOS
Warm Reboot
>
Submit
reset cold
tab, select
Cold Reboot
3-20). Follow the return
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
.
>
Submit
.