Trouble-clearing procedures
DBINVALID
....................................................................................................................................................................................................................................
Note: The redundant Equipment Controller, if one is in its slot, will synchronize with
the active Equipment Controller.
...................................................................................................................................................................................................
If this condition occurs after user panel replacement, a database backup (previously saved
2
for this NE) must be restored to the NE from a remote database backup and restore server,
with the special keyword "force".
The steps are as follows:
1. Re-provision the user panel OADM port details for this NE.
2. Re-provision the static routing and gateway information for this NE.
3. Re-provision the database server information, perform the steps in
Database" (p. 3-13)
restore procedures.
4. Enter the CLI command
from a remote server to the NE.
...................................................................................................................................................................................................
If this condition occurs after the replacement of a Equipment Controller, and there is no
3
protection (redundant Equipment Controller), then perform the steps in
Database" (p. 3-14)
Note: It is crucial to have the backup database be a duplicate of the one running on
the NE prior to replacing the Equipment Controller. Any data not backed up will be
lost and may result in lost services and interruption in traffic.
...................................................................................................................................................................................................
Review of the NE logs may provide an indication of the corruption of the database by
4
way of a failed audit function resulting in CRC errors. If the DBINVALID condition is
present due to a corruption of the database, then perform the steps in
Database" (p. 3-14)
database backup file.
E
N D
O F
...................................................................................................................................................................................................
DBMEMTRF

DBMEMTRF (Database synchronization failure)

....................................................................................................................................................................................................................................
1830 PSS-36/PSS–32/PSS-16/PSS-4
8DG60888CAAA Release 3.6.0 and 3.6.1
Issue 1 June 2011
and
"Restoring a Database" (p. 3-14)
config database restore force
to restore the database to the Equipment Controller.
to restore the database to the Equipment Controller from a valid
S T E P S
DBINVALID (Database invalid)
"Backing Up a
for the database backup and
to bring the database
"Restoring a
"Restoring a
2-65